Описание продукта

Sanitary Clamp Type Turbine Flow Meter 0


1. Product Brief Introduction:

HQ-LWGY turbine flowmeter is a precision flow measurement instrument that can be used to measure the flow rate and total amount of liquids when paired with corresponding flow integrator instruments. Liquid turbine flow meters are widely used in measurement and control systems in fields such as petroleum, chemical, metallurgical, and scientific research. Liquid turbine flow meters equipped with sanitary fittings can be applied in the pharmaceutical industry. Intelligent turbine flowmeters is suitable for measuring the flow rate of oil solvents.


2. Product Features:

HQ-LWGY liquid turbine flowmeter is a precision measuring instrument that adopts advanced microprocessing technology. It has the characteristics of strong functionality, wide flow range, simple operation, and easy installation and use. The liquid turbine flowmeter, which is widely used in the fields of petroleum, chemical, metallurgy, scientific research, and equipped with sanitary fittings, is mostly used in the pharmaceutical industry. The product has the following advantages:

① Low pressure loss, impeller with anti-corrosion function.

② Can display on-site, instantaneous flow rate, cumulative total amount.

③ The whole machine has low power and can work for a long time with the internal battery, making it an ideal passive display instrument.

④ Using EEPROM for power down protection of cumulative flow meter coefficients, with a protection time greater than 10 years.

Sanitary Clamp Type Turbine Flow Meter 1 

 

3. Product Performance:


Nominal diameter: pipeline type DN4~DN200; insertion type DN200~DN2000

Accuracy level: pipeline type ± 0.5 grade, ± 1.0 grade; insertion type ± 2.5 grade, ± 1.5 grade 

Medium temperature: measuring liquid -20 ℃~120 ℃

Ambient temperature: -20 ℃~+50 ℃

Medium temperature: measuring liquid: 0 ℃~80 ℃ special: -20 ℃~150 ℃

Atmospheric pressure: 86KPa~106KPa

Pressure rating: 1.6MPa, 2.5MPa, 6.4MPa, 25MPa

Explosion-proof rating: Ex db IIC T6 Gb Ex db ia IIC T6 Ga

Connection type: threaded connection, flange connection, insertion type, etc


Sanitary Clamp Type Turbine Flow Meter 2

Sanitary Clamp Type Turbine Flow Meter 3

4. Working Principle:


The structure of the sensor, which mainly consists of a housing, a front guide frame, an impeller, a rear guide frame, a clamping ring, and a magneto electric induction converter with an amplifier. 

When the measured fluid flows through the sensor, the impeller inside the sensor rotates with the help of the kinetic energy of the fluid, and the impeller is the magnetoresistance in the periodic electromagnetic induction system. Periodically changing the magnetic flux passing through the coil to generate an electrical pulse signal, which is amplified by an amplifier and transmitted to the corresponding flow integrator for flow or total measurement.  

Sanitary Clamp Type Turbine Flow Meter 4

Sanitary Clamp Type Turbine Flow Meter 5


5. Technical Specifications:


(1) Measurement range of liquid turbine flowmeter:


Instrument Caliber Normal Flow Expanded Flow Conventional Tolerable Pressure Maximum Tolerable Pressure
(mm) Range (m³/h) Range (m³/h) MPa MPa
DN 4 0.04 - 0.25 0.04 - 0.4 6.3 32
DN 6 0.1 - 0.6 0.06 - 0.6 6.3 32
DN 10 0.2 - 1.2 0.15 - 1.5 6.3 32
DN 15 0.6 - 6 0.4 - 8 6.3 32
DN 20 0.8 - 8 0.45 - 9 6.3 32
DN 25 1 - 10 0.5 - 10 6.3 32
DN 32 1.5 - 15 0.75 - 15 6.3 32
DN 40 2 - 20 1 - 20 6.3 32
DN 50 4 - 40 2 - 40 2.5 25
DN 65 7 - 70 3.5 - 70 2.5 25
DN 80 10 - 100 5 - 100 1.6 25
DN 100 20 - 200 10 - 200 1.6 16
DN 125 25 - 250 12.5 - 250 1.6 16
DN 150 30 - 300 15 - 300 1.6 16
DN 200 80 - 800 40 - 800 1.6 16


(2) Electrical performance indicators

Working power supply: External power supply:+24VDC

Internal power supply: 3.6V lithium battery (lithium battery can be used for more than two years)

Output mode: Pulse signal 4~20mA current signal, corresponding to flow rate 0~Qmax, 20mA corresponding flow rate can be set by the user themselves. RS485 communication: capable of transmitting instantaneous and cumulative traffic, as well as time and date

(3) Explosion proof mark: Exd Ⅱ BT4

(4) Protection level: IP65

Sanitary Clamp Type Turbine Flow Meter 6


6. Selection


HQ-LWGY Series Liquid Turbine Flowmeter Selection Table


HQLW Turbine Flow Meter
Instrument Type Y Battery powered on-site display type
GB 4-20mA two wire current output, remote transmission type
GY Basic type, powered by+5-24VDC
YA On site display/4-20mA two-wire current output
Type A Turbine flowmeter (ordinary type)
B High pressure turbine flowmeter
C Insertion type turbine flowmeter
D Split type turbine flowmeter
E Clamp type turbine flowmeter
F Threaded turbine flowmeter
G Wireless remote transmission turbine flowmeter
H Solar powered turbine flowmeter
I Solar powered turbine flowmeter
Nominal Diameter 4 DN4
... ...             (Find the comparison table of nominal diameter numbers of sensors for details)
300 DN300
Explosion-proof Type B Explosion proof EX
X Intrinsically safe
Accuracy Grade A 0.2
B 0.5
C 1
D 1.5
Measuring Medium A Acidic liquid
B Ordinary liquid
C High temperature liquid
D Alkaline liquid
Installation Method A Standard threaded connection
B Customized threaded connection
C flange connection
D Plug-in
Output Signal G GPRS wireless remote transmission
H No output (built-in lithium battery header display)
R Communication output
S Pulse output
T 4-20mA current output (two-wire system)
Power Supply Method 1 DC24V
2 AC220V (with power converter)
3 Battery-powered
4 Battery+DC24V dual power supply
5 solar-powered
Pressure Rating A 0.6 MPa
B 1.0 MPa
C 1.6 MPa
D 2.5 MPa
E High voltage customization
Valve Body Material 1 Stainless Steel 304
2 Stainless Steel 316
3 PVC


Nominal Diameter Flow Range Description
DN
4 4mm, normal turbine flow range 0.04~0.25m³/h
Wide range turbine is 0.04~0.4m³/h
6 6mm, normal turbine flow range 0.1~0.6m³/h
Wide range turbine is 0.06~0.6m³/h
10 10mm, normal turbine flow range 0.2~1.2m³/h
Wide range turbine is 0.15~1.5m³/h
15 15mm, normal turbine flow range 0.6~6m³/h
Wide range turbine is 0.4~8m³/h
25 25mm, normal turbine flow range 1~10m³/h
Wide range turbine is 0.5~10m³/h
40 40mm, normal turbine flow range 2~20m³/h
Wide range turbine is 1~20m³/h
50 50mm, normal turbine flow range 4~40m³/h
Wide range turbine is 2~40m³/h
80 80mm, normal turbine flow range 10~100m³/h
Wide range turbine is 5~100m³/h
100 100mm, normal turbine flow range 20~200m³/h
Wide range turbine is 10~200m³/h
150 150mm, normal turbine flow range 30~300m³/h
Wide range turbine is 15~300m³/h
200 200mm, normal turbine flow range 80~800m³/h
Wide range turbine is 40~800m³/h


7.  Installation


7.1 Dimensions and Installation of HQ-LWGY Liquid Turbine Flow Meter


Sanitary Clamp Type Turbine Flow Meter 7


Note: Flange connection size: in accordance with GB/T9119-2000 standard


7.2 Installation of HQ-LWGY liquid turbine flowmeter


(1) Installation Site

The flowmeter should operate under conditions where the temperature of the measured liquid is -20~+120 ℃ and the relative humidity of the environment is not greater than 80%. From the perspective of maintenance convenience, it should be installed in a location that is easy to disassemble and replace, and avoids the impact of piping vibration or stress. Considering the protection of the amplifier, efforts should be made to avoid exposing it to strong thermal radiation and radioactivity. At the same time, it is necessary to avoid the influence of external strong electromagnetic waves on the detection coil. If it cannot be avoided, a shielding cover should be added to the amplifier of the sensor, otherwise interference will seriously affect the normal operation of the display instrument.


(2) Installation location

The flowmeter should be installed horizontally, and the arrow indicating the flow direction on the sensor should match the direction of fluid flow during installation.


(3) Key points of piping

① In order to mitigate the impact of liquid vortex and uneven cross-sectional flow velocity on measurement, necessary straight sections or rectifiers should be installed at the inlet and outlet of the sensor. Generally, the straight pipe section of the upstream part (inlet) is required to be (15-20) D (D is the nominal diameter of the sensor) The downstream part (the length of the straight pipe section at the outlet is 5D), while the diameter of the straight pipe and the sensor are connected

In addition, the length of the upstream straight pipe section should be determined based on the status of the piping in front of the sensor. Generally, the following recommendations are recommended

When tuning contraction: L=15D for single bend pipe joint: L=20D

When double bent pipe joint: L=25D (one plane) L=30D (two planes)

When using a right angled bend joint: L=40D

When there is a straight stop valve: L=20D (valve fully open)

L=50D (valve half open)

Besides. In order to achieve more effective eddy currents and improve measurement accuracy, a rectifier composed of a bundle of conduits can be inserted into the straight pipe section of the upstream section. In French, the length of the straight pipe section upstream of the rectifier is (10~20) D.

② In order to ensure the normal operation of the sensor and improve its lifespan, a filter with a mesh size of 3-9 days/cm2 should be installed on the pipeline in front of the sensor to remove impurities in the flow. In general, the mesh with a larger diameter is sparse, while the mesh with a smaller diameter is dense. To ensure the normal operation of the sensor, a filter should also be selected according to the actual usage situation.

③ When welding the inlet flange of the sensor, it is necessary to pay attention to the absence of protruding parts inside the pipe. When connecting the inlet flange, the outer edges of the two flanges should be completely aligned, and the ring should not be exposed inside the tube. Eccentric reducing joints will cause uneven distribution of flow velocity, so they cannot be used.

④In order to ensure the maintenance needs under the working diameter, cut-off valves (globe valves) should be installed on the front and rear pipelines of the transmitter, and bypass pipelines should also be set up.

The flow control valve should be installed downstream of the sensor. When using the sensor, the upstream shut-off valve must be fully opened to avoid turbulence in the upstream fluid.

When the flow rate through the sensor exceeds the upper limit of the flow range, the bearing will wear faster due to high speed. For this reason, when excessive flow is expected, the flow control valve installed in the downstream section can be used to regulate the flow.

⑥ Due to the significant measurement error caused by gas in the pipeline, special attention should be paid to the presence of gas in the measured liquid during installation, especially for the measurement of light liquid media, which must be equipped with an air separator. The piping from the air separator to the sensor should be installed at an upward tilt to allow gas to accumulate here. In addition, attention should be paid to the control of downstream back pressure of the sensor. The magnitude of the back pressure can be calculated according to the following formula: Pa ≥ △ P+1.25Pv

In the formula: Pa - downstream back pressure:

Δ P - pressure loss of the sensor at maximum flow rate;

   Pv - The saturated vapor pressure of the medium at the highest operating temperature.

⑦ When installing sensors on a new pipeline, to avoid impurities from entering the sensor, an empty pipe should be used instead of the sensor. After running for a period of time, it should be confirmed that the impurities have been eliminated before replacing the sensor.

⑧ When installing sensors with nominal pressures of PN16 and 25Mpa, a small amount of lubricating oil should be applied to the cold cutting edge of the sleeve, the thread of the nut, and various contact parts. The nut and sleeve should be sequentially fitted onto the pipe, and then the pipe should be inserted into the bottom of the tapered hole of the sensor housing. Place the sleeve in place, and while tightening the nut, rotate the pipe until it stops moving, and then tighten the nut 1-11/3 turns.

Sanitary Clamp Type Turbine Flow Meter 8 

Intelligent Turbine Flow Meter Ordering Notice:

① When ordering this product, users should pay attention to selecting appropriate specifications based on the nominal diameter of the pipeline, flow range, nominal pressure, maximum pressure of the medium, temperature range of the medium, and environmental conditions.

② Explosion proof grade requirements must be indicated for use in hazardous areas.

③ Flow meters are generally of the basic type with pulse output for operating conditions. If other accessories and output functions are required, please specify them when placing an order. When placing an order, please fill in the following format in detail and correctly.